AC input current rating. Call For Lowest Price! Add to Cart. 75 in. Accessories Juniper Juniper MX-series MX240 Installation Instructions Manual. Click here to jump to more pricing!. MX960 AC Power Supply Description. Normal-Capacity Power Supply. A component is not powered on if the PEM cannot meet the worst-case power requirement for that. When an SRX5K-SCB was used , the third SCB slot was used as an FPC. Installing an MX960 DC Power Supply. Save on Juniper PWR-MX960-4100-AC-BB. DCJ41001-01P Juniper Mx960 4100W Ac PSU Power Supply. Data Sheet 1 Product Overview Juniper Networks MX SeriesThe internal power budgeting algorithm always tries to load balance power distribution between the PEMs by using the following table: max load(Amp) difference of 3. SCB slot 0. Mixing currents can damage the device. $150. Network Management and Monitoring Guide navigate_next. MX960 DC Power Supply. Starting in Junos OS Release 20. The cooling system power requirement does not need to be deducted from the output power budget of the power supply. Each AC power supply faceplate contains three LEDs that indicate the status of the power supply (see Table 1and Table 2 ). 0 in. Remove the powered-off DPC from the MX960 router. 0% between power supplies from 50% up to 100% . Turn on the power to the external management device. The power source cables might be labeled (+) and (–) to indicate their polarity. To remove a normal-capacity AC power supply (see Figure 1): Move the AC input switch in the chassis above the power supply in slot 0 to the off (O) position. Get Fast Service and Low Prices on Juniper Networks PWR-MX960-DC-S MX960 Power Entry Module DC Spare Related Products and Over 500,000 Other Products at Provantage. Attach the negative ( ) DC source power cable lug to the terminal. To install an MX960 DC high-capacity DC power supply: Verify that the power switch on the power supply is in the off (O) position. Replace the clear plastic cover over the terminal studs on the faceplate. Power supply second generation Jump to Best Answer. The cooling system components also connect to the. That means all of the power supplies are sharing the load. The 740-027760 has been fully refurbished by Serverworlds. The AC power supplies support Power over Ethernet (PoE+) in EX4300-24P, EX4300-24P-S, EX4300-48P, EX4300-48P-S, EX4300-48MP, and EX4300-48MP-S models. Here is what I show for high power. Each DC power supply faceplate contains three LEDs that indicate the status of the power supply (see Table 1). Removing a Normal Capacity MX960 AC Power Supply on page 235 2. #MX960BASE-AC List Price: $83,916. Unplug the power cord from the power source receptacle. txt) or read book online for free. The serial number label is located on the DC power supply faceplate under the circuit breaker switch (see Figure 4 ). After powering on a power supply, wait at least 60 seconds before turning it off. The alarm contact port is used to generate LED alarms on the router and to turn external devices on or off. The Juniper PWR-MX960-4100-DC-S is a DC power supply designed for the MX960 router. pdf), Text File (. MX960 14 Slot Base Chassis with 2 Fan Trays, 3 AC Power Supplies, 2 SCB, 1 RE. To operate the. A Failed condition triggers the red alarm LED on the craft interface. Each DC power supply weighs approximately 3. MX960 Midplane Description The midplane is located toward the rear of the chassis and forms the rear of the card cage. Table 1 summarizes the physical specifications for the router chassis. A. The power supplies connect to the midplane, which distributes the different output voltages produced by the power supplies to the router components, depending on their voltage requirements. CHAS-MX104-S Juniper MX104 3D Universal Edge Router with 8x Expansion Slots (Refurbished) Was: $6,882. Syntax (QFabric System) show chassis environment cb < slot interconnect-device interconnect-device-name > < interconnect-device interconnect-device-nameslot >. An EX9214 switch is configurable with two or four AC power supplies. Figure 1 – Physical Cryptographic Boundary (Left to Right: MX80, MX104, MX240, MX480, MX960) Figure 2 – MIC. To install a DC power supply (see. Do not mix AC and DC power supply modules within the same device. Table 2 provides. Table 1 lists the MX960 base system and cooling system power requirements. Connect the power cord to the power supply source. Buy Juniper Networks Power Supply Accessory PWR-MX960-DC-S. The command output displays the status of both power supplies installed in the router. To remove a normal-capacity AC power supply (see Figure 1): Move the AC input switch in the chassis above the power supply in slot 0 to the off (O) position. The command shuts down the Routing Engines cleanly, so their state. Power. Troubleshooting the MX960 PICs. Description. Each receptacle requires a dedicated AC power feed and a dedicated breaker. To connect the AC power cord:Power Supply Juniper Juniper MX-series MX960 Installation Instructions Manual. 2 mm 2 ), minimum 60°C wire, or as required by the local code. Phillips (+) screwdrivers, numbers 1 and 2. Connect AC Power to an MX10008. Juniper MX960 24 Bo co thc t p. Aug 21, 2015, 6:37 AM. Mã/Product: Mô tả /Description Routing Engines of Juniper MX960 MX960BASE3-AC 14 slot MX960 base 3 chassis, AC power MX960BASE-AC 14 slot MX960 base chassis with 2 fan trays, 3 AC power supplies, 2 SCBs, 1 REThis article explains how to troubleshoot power entry module-related (PEM) minor alarms on Juniper MX devices. This article describes the Flexible PIC Concentrator (FPC) misconfiguration alarm, which is generated due to high power consumption by the Dense Port Concentrators (DPCs). Turn on the power to the external management device. Plug the power cord into the corresponding appliance inlet located in the chassis directly above the power supply. The AC or DC power supply modules directly plug on to main board and are placed on the right side of the rear chassis. We would like to show you a description here but the site won’t allow us. Normal-Capacity Power Supply. In the DC power configuration, the router contains either two or four DC power supplies (see Figure 1), located at the lower rear of the chassis in slots PEM0 through PEM3 (left to right). CAUTION: You must ensure that power connections maintain the proper polarity. See Figure 1 for older legacy routers, and see Figure 2 for routers shipping with the new power supplies (MX960-PSM-5K-AC or MX960-PSM-HV). PTX10008 Power System | Juniper NetworksProduct Type: Proprietary Power Supply Compatibility: Juniper Networks MX960 3D Universal Edge Router Manufacturer Part Number: PWR-MX960-4100-AC-BB Output Power: 4100 W Form Factor: Internal Manufacturer: Juniper Networks, Inc. JUNIPER POWER SUPPLY 4100W 200-240V 14-12A 50-60HZ FOR JUNIPER MX960 UNIVERSAL ROUTING PLATFORM ENCLOSURE CHASSIS - OUTPUT +46V+56V -. We recommend that you use a dedicated customer-site circuit breaker rated for 25 A (–48 VDC) minimum, or as required by local code. Power Requirements for an MX960 Router. Place the grounding cable lug over the grounding points on the rear of the chassis. Search Get a free quote. All major hardware components including the power system, the cooling system, and the control board are fully. Both AC receptacles are located on front panel of the power supply. When the ACX2200 router are operating normally and both power supplies are switched on, load sharing between them occurs automatically. Call 415-230-4353. The terminal studs may be damaged if excessive torque is applied. Connecting an MX480 AC Power Supply Cord. A system cannot operate with a mix of AC and DC power supplies. Unplug the power cord from the appliance inlet on the power supply. (70. MX480 is a single power zone. Remove and replace the SCB-MX in slot 1 on the router with the SCBE-MX. For existing power supplies, each inlet requires a dedicated AC power feed and a dedicated 15 A (250. MX960 Router Grounding Cable Specifications. "show chassis alarm" showed > me that. The MX960 chassis provides redundancy and resiliency. Figure 1 and Figure 2 show the MX204 PSMs. (2. Specification. Table 1 describes the functions of the host subsystem LEDs. The MX960-PSM-HV (HVAC/HVDC) power supply has one power inlet on front panel of the power supply rated at 30 A. Replacing the MX960 Air Filter Tools and Parts Required to Replace MX960 Hardware Components To replace hardware components, you need the tools and parts listed in Table 1 . The 740-027760. 549 likes · 1 talking about this · 27 were here. Description: Juniper MX960 SCB-MX Module. (58. Juniper Family Health is a premier naturopathic medical clinic in the heart of. Connecting an MX480 DC Power Supply Cable. SRX100H. In two-feed mode, the power supplies provide power at full capacity (4100W). 2 is the first release in. The modules exclude the power supplies from the requirements of FIPS 140-2. Page 8 MX960 Ethernet Services Router DC Power Supply Installation Instructions Attach the positive (+) DC source power cable lug to the terminal. Juniper Networks_MX960 Hardware Guide - Free ebook download as PDF File (. Each high-voltage second-generation universal (MX960-PSM-HV) power supply faceplate contains three LEDs that indicate the status of the power supply (see Figure 1). EX4300, 550W DC Power Supply Airflow-In (Power Cord needs to be ordered separately), PSU-Side Airflow Intake. Find quality power supply accessory products at discounted prices. Ensure that the power supplies are fully inserted in the chassis and the latches are secure. Product Model: PWR-MX960-4100-DC-BB Brand Name: Juniper. The JNP10008-SF3 switch fabric requires the JNP10K-PWR-AC2 or the JNP10K-PWR-DC2 power supply. ADD TO CART. 77 Call For Lowest Price! Add to Cart. 42. Click here to jump to more pricing!. For details on this power supply, see JNP10K-PWR-AC2 Power Supply. The MX960 has been proven in the world’s largest service provider, cable, mobile, and data center networks, offering 12 Tbps of system capacity in support of business and residential broadband services as well as peering and provider edge applications. txt) or read book online for free. Hello, we have bought two Juniper MX960 and we're having serious trouble with power supplies triggering alarms and then clearing alarms a few seconds later: 2x RE-S-X6-64G. Each power supply has a. Ethernet services router (242 pages) Network Hardware Juniper MX240 - UPGRADING Manual. Table 1 lists the MX960-PSM-HV (HVAC or HVDC) power supply electrical specifications. Connecting Power to an MX960 Router with High-Voltage Second-Generation Universal (HVAC or HVDC) Power Supplies | Juniper NetworksEach DC power supply weighs approximately 3. Normal-Capacity Power Supply. density with space and power efficiency, the MX304 helps network operators overcome the challenges of a hyper-connected world and profitably deliver the widest variety of services and applications. Enhanced MX SCB. This could be a false alarm. Enhanced MX SCB. 1R2 firmware on any of the Juniper Networks MX 3D Universal Edge Routers listed in Table 1 below. 9 W/Gb. If you plan to operate a maximally configured DC-powered router with normal capacity power supplies, we recommend that you provision at least 116 A (58 A per feed) @ –48 VDC (nominal) for the system. $929. MX960 PIC Description. (2. My guess is it will depend on how much power is allocated. The MX480 chassis footprint is only 3 Rack Units (or the equivalent of 5. When two power supplies are present, they share power almost equally within a fully populated system. $799. One end of the cable has an Anderson APP-400 connector, the other end of the cable is bare wire. Look at the output of show chassis power and see what the allocated power is. To convert from AC to DC, use the following procedures. For this configuration, output power is 2935 W. AC nominal input voltage. The LEDs labeled RE0 show the status of the Routing Engine in slot 0 and the SCB in slot 0. If one power supply fails or is removed, the remaining power supply assumes the entire electrical load without. Table 1 lists the MX960-PSM-HV (HVAC or HVDC) power supply electrical specifications. 1F5. MX960 (4) Power connector, Power over Ethernet Power LEDs MX240 (2), MX480 (2),To install an MX960 DC high-capacity DC power supply:If the cooling system temperature is above a certain level, the power supplies are automatically cut off. Each DC power supply faceplate contains three LEDs that indicate the status of the power supply (see Table 1). Each of the high-capacity power supplies has a corresponding AC receptacle located in the MX960 chassis directly above the power supply. Attach the power cable to the DC power source. asoltanian1979 12-23-2020 13:24. That means all of the power supplies are sharing the load. Check the status of a PIC by issuing the show chassis fpc pic-status. DPC slots 2 – 5. $949. 70 W. Juniper MX240. Best Selection, Highest Quality, Most Knowledgeable Reps. The coupler is type C19 as described by International Electrotechnical Commission (IEC) standard 60320. 1, after graceful routing engine switchover (GRES), the new primary Routing Engine sends a single warmStart notification. 1700 W. In Junos OS 14. These items have beenLook in the smarts/conf/discovery directory of one of your AMPM's and open the oid2type_Juniper. Mã/Product: Mô tả /Description Routing Engines of Juniper MX960 MX960BASE3-AC 14 slot MX960 base 3 chassis, AC power MX960BASE-AC 14 slot MX960 base chassis with 2 fan trays, 3 AC power supplies, 2 SCBs, 1 RETitle: Upgrading MX240, MX480, and MX960 3D Universal Edge Router Fan Trays and Power Supplies Author: Juniper Networks SubjectFigure 64: MX960 with High-Capacity DC Power Supplies Installed. The MX2000 line supports N+1 fabric redundancy, control plane redundancy, N+N power feed redundancy, and even N+1 power supply module redundancy. Installing an SFP or XFP Transceiver into an MX960 DPC, MPC, MIC, or PIC. There is no standard color coding for DC power cables. 1F5. Providing quality memory products since 1986 Blog 1-800-821-3354 Call: 1-800-821-3354Save on Juniper SCB-MX960-S. Juniper Networks MX Series 3D Universal Edge Routers are helping network operators successfully transform their networks and. Replacing an MX480 DC Power Supply Cable. The power supply status is also reflected in two LEDs on the craft interface In addition, a power supply failure triggers the red alarm LED on. The MX480 router is configurable with two, three, or four AC power supplies or two or four DC power supplies. For this configuration, output power is 3225 W. The left pair is sized for M6 screws, and the right pair is sized for UNC 1/4-20 screws. • The MX960 is ideal for large service provider and cloud networks, cable applications, and mobile service cores. The power supplies do not contain any security relevant components and cannot affect the security of the module. Fast shipping to. 4, the output of the show chassis hardware models operational mode command displays the enhanced midplanes FRU model numbers (CHAS-BP3-MX240-S, CHAS-BP3-MX480-S or CHAS-BP3-MX960-S) based on the router. Each table lists the first Junos OS release in which the MPC supports the MIC. My guess is it will depend on how much power is allocated. The power supply status is also reflected in two LEDs on the craft interface In addition, a power supply failure triggers the red alarm LED on the craft interface. Buy a Juniper Networks MX960 5000W AC Power Supply mo and get great service and fast delivery. Step-by-step descriptions are given for replacement of the various parts in the chassis. Transceiver. For optimum router performance, verify the condition of the power supplies. Xcvr. Mixing currents can damage the device. To install an MX960 DC high-capacity DC power supply: Verify that the power switch on the power supply is in the off (O) position. SUPPLY Victoria, Victoria, British Columbia. The MX960 router is 16 rack units (U) tall. The MX2008, MX2010, and MX2020 routers support the same power modules AC, DC, 240 V China, and universal PSMs and PDMs. The hardware system is fully redundant, including power supplies, fan trays, Routing Engines, and Switch Control Boards. The conversion of an MX960 router from AC to DC or DC to AC should be performed with the system completely powered off. Step 1: Prepare the Site for MX960 Installation. Mx series universal edge router fan trays and power supplies (35 pages) Network Router Juniper MX240 Instruction For Upgrading. Each power cord. SCBE-MX960-S. View and Download Juniper MX960 hardware manual online. Maximum output power. Save on Juniper PWR-MX960-4100-AC-R. The SCB-MX960-S-G is a fully tested Juniper MX960 SCB-MX Module. DPC/MPC slot 0 – 1. Power Distribution—The router power. Check MX204 price, and buy Juniper MX Series Base Product Bundles with best discount. In one-feed mode, the power supplies output power at a reduced capacity (1700W). Modular MX Series Platforms MX960, MX480, and MX240 Universal Routing Platforms areWe would like to show you a description here but the site won’t allow us. Like the larger MX10000 routers, the MX10004 supports Juniper Networks. Additional clearance is also required to accommodate the depth of the MX960 high-capacity power supplies; they extend beyond the chassis as shown in Table 1. The power supply has a hot-swappable design, which allows for easy replacement without disrupting network services. 110 W. The maximum torque rating of the terminal studs on the DC power supply is 58 lb-in. The chassis is shown with the extended cable manager. The SCB-MX960-S-G. 2 out of 5 stars 1,628Discussion: [j-nsp] MX960 transient errors on high capacity AC power supplies. 7/16-in. In the DC power configuration, the router contains either two or four DC power supplies (see Figure 1), located at the lower rear of the chassis in slots PEM0 through PEM3 (left to right). Posted 04-01-2013 13:48. Availability: Available by Quote. Description. In the DC power configuration, the router contains either two or four DC power supplies (see ), located at the lower rear of the chassis in slots (left to. The maximum torque rating of the terminal screws on the DC power supply is 23 lbf-in. Table 1 lists the details of the 350 W, 715 W, 1100 W, and 1400 W AC power supplies used in EX4300 switches. SCB slot 0 – 1. 1 and 14. To supply sufficient power, terminate the DC input wiring on a facility DC source. Switch on the dedicated customer site circuit breaker. The LEDs labeled RE0 show the status of the Routing Engine in slot 0 and the SCB in slot 0. A Failed condition triggers the red alarm LED on the craft interface. Verify that an external management device is connected to one of the Routing Engine ports (AUX, CONSOLE, or ETHERNET). The MX10003 is a small router with CUPS user plane capabilities, 3GPP-Sx interoperability, in addition to full routing, switching, security, and high availability features. In a non-redundant configuration the SCBE3-MX provides fabric bandwidth of up to 1. Note: If only one power supply is installed in your EX4300 switch, you need to power off the switch before removing the power supply. Knowledge Base. Users may find that the QFX10008 and QFX10016 devices (running releases prior to Junos OS 19. The hardware system is fully redundant, including power supplies, fan trays, Routing Engines, and Switch Control Boards. To power off the router: On the external management device connected to the Routing Engine, issue the request system halt both routing operational mode command. conf. A minimum of two AC nominal 220 VAC 20 amp power cords are required for this procedure. Power Allocation by Zones in the Juniper MX Series PEM0 PEM1 PEM2 PEM3; MX960: Lower Fan. Save on Juniper PWR-MX960-4100-AC-S. The MX204 is a space- and power-optimized router delivering ultra-high port density and throughput while consuming just 0. Connecting Power to an AC-Powered MX960 Router with High-Capacity Power Supplies. The PICs are not functioning normally. Routinely check the status LEDs on the power supply faceplates and the craft interface to determine if the power supplies are functioning normally. Table 2 lists the FRU power requirements for Switch Control Boards (SCB), Routing Engines, Modular Port Concentrators (MPC), Modular Interface Cards (MIC), Dense Port Concentrators (DPC), and Flexible PIC Concentrators (FPC). Power Modules – Power Module - Juniper MX960 3D Universal Edge Router $ 5,000. To power on an AC-powered router:Connecting Power to an AC-Powered MX960 Router with High-Capacity Power Supplies. Attach an ESD grounding strap to your bare wrist, and connect the other end of the strap to an ESD grounding point. The MX960 router uses either AC, DC, or universal (HVAC or HVDC) power supplies. 8 lb (1. 99. The DC power system operates with feeds of 60 A or 80 A current limited. See Figure 1 and Table 1. Note: Troubleshooting the MX960 Power System. - MX960 Power Supply LEDs on the Craft Interface - MX960 DPC and MPC LEDs on the Craft InterfacPower on a DC-Powered MX304 Router. For information about software issues, see the Junos OS Release Notes. Page 2 Figure 1: Removing a Power Supply Before Installing the MX960 Router Removing the Standard Cable Manager Before Installing an MX960 Router Without a Lift To remove the standard cable manager. Figure 4 ). Connect Power to an AC Router with High-Capacity Power Supplies | 15 Connect Power to a DC Router with Normal-Capacity Power Supplies | 19 Connect Power to a DC Router with High-Capacity Power Supplies | 21 Step 7: Perform Initial Software Configuration ii. Estimated between Tue, Dec 5 and Wed, Dec 20 to 98837. Use this guide to install hardware and perform initial software configuration, routine maintenance, and troubleshooting for the MX960 5G Universal Routing Platform. You can connect up to four input alarms and two output alarms. Special Order. The 480 just has physically larger chassis and 2 more power supplies. Figure 1: AC Plug Types. MX480 DC Power Supply LEDs. Check the LEDs on each power supply faceplate. If an AC power supply is correctly installed and functioning normally, the LED’s light steadily, and the LED is not lit. For optimum router performance, verify the condition of the power supplies. The conversion of an MX960 router from AC to DC or DC to AC should be performed with the system completely powered off. 1 New product. Providing quality memory products since 1986Cable Type. The power supplies connect to the midplane, which distributes the different output voltages. MX10004 Hardware Overview. Figure 1 shows a typical DC source cabling arrangement. JPSU-550-DC-AFI. Note:Align the red line along the bottom of the internal strap with the bottom of the connector and snap gently into place. Move the input mode switch to position 0 for one feed or position 1 for two feeds (see Figure 1 ). 250 VAC, 60 Hz AC. MX960, MX480, and MX240 Universal Routing Platforms are modular, chassis-based platforms. The conversion of an MX960 router from AC to DC or DC to AC should be performed with the system completely powered off. MX960 guideFixed-Configuration MX Series Platforms. This topic lists outstanding hardware issues with the MX960 Universal Routing Platform. NEXT arrow_forward DC Power Source Cabling for the MX960 Router. This enables Juniper customers to select the platform that best addresses their unique business goals and satisfies their scale, density, resiliency, space, power, and value-added service requirements without compromising on quality or features. 3X75-D30, FIPS Evaluated Configuration Guide for MX960, MX480, and MX240 Devices navigate_next;. The datacenter. Ethernet services router dc power supply (16 pages). The power source cables might be labeled (+) and (–) to indicate their polarity. Installing a left-angled Power Cord on MX960 Routers with High-Capacity AC Power Supplies on page 247. 04 kg). com. 20 Call For Lowest Price! Add to Cart. Verify that an external management device is connected to one of the Routing Engine ports on the Craft Interface (AUX, CONSOLE, or ETHERNET). 3x SCBE-2-MX. 2. The 48 VDC facility must be equipped with a circuit breaker rated 40 A (–48 VDC), or 60 A (–48 VDC), and the grounding cable must be minimum 6 AWG, or as required by the local code. A system cannot operate with a mix of AC and DC power. It is important to verify that the PEM is receiving the correct. Find great deals and sell your items for free. High Efficiency: The Juniper PWR-MX960-4100-AC-S proprietary internal power supply is highly efficient, with an efficiency rating of up to 94%. MX480 AC Power System. Attach an ESD grounding strap to your bare wrist, and connect the other end of the strap to an ESD grounding point. More than likely we will order the 208V/30AMP A/B Power. Clock Cable for Enhanced MX Switch Control Board to allow BITS/GPS inputs. To take the DPC offline and preserve the state after a reboot, use the set chassis fpc slot-number power off command from configuration mode. However in case 1 x PEM is not receiving power (like Input Power Supply is gone ) but PEM itself is physically there then Juniper router reports 2 x chassis alarms , with one being that 'PEM Not Ok' while other 'PEM. Spedizione internazionale standard. This article clarifies that the message may be a false one and recommends confirming the message validity by checking the. Overnight installation of 3 Juniper Networks MX960 routers across 2 London datacenters. 6 terabits per second (Tbit/s) of. 11 A @ 240 VAC maximum. Let go of the locking pin in the release lever. Save 27%. Here is what I show for high power. My guess is it will depend on how much power is allocated. MX960 AC Power Supply Description Installing a MX960 AC Power Supply or High-Voltage Second-Generation Universal (HVAC or HVDC) To install an AC or universal (HVAC/HVDC) power supply (see Attach an. The MX480 router uses either AC or DC power supplies. After powering off a power supply, wait at least 60 seconds before turning it back on. Juniper Networks MX-MPC3E-3D Edge Router Supports 100GbE/40GbE/10GbE Interfaces. Description: Juniper MX960 Fan Assembly. Part Number: 530-036423 Revision 02 This document describes the necessary steps to be taken to upgrade any Juniper Networks MX Series 3D Universal Edge Router chassis to higher capacity cooling and higher capacity power. MX960, MX480, and MX240 Universal Routing Platforms are modular, chassis-based platforms. 57. Best Selection, Highest Quality, Most Knowledgeable Reps. Products. To connect the AC power cords to. DPC/MPC slots 0 – 5. MX480, and MX960 Devices navigate_next; Junos OS Release 20. 2 mm 2 ), minimum 60°C wire, or as required by the local code. pdf), Text File (. 6 Tbps per slot and the 13 RU, 76. Preventing Electrostatic Discharge Damage to an MX960 Router. The Juniper MX960 Universal Edge router delivers switching and carrier-class Ethernet routing to support a wide range of residential and business applications and services, like next generation broadband multiplay services, high-speed transport and VPN services and high-volume internet data center networking. 5 mm) nut driver or socket wrench. 9. Our Price: $22,821. Best Selection, Highest Quality, Most Knowledgeable Reps. Product Description.